2018 irc roof sheathing requirements
Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. R803.1 Lumber sheathing. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. The installation of wood shakes shall comply with the provisions of this section. Self-adhering polymer-modified bitumen. A liquid-applied protective coating that complies with Table 905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. roof sheathing, skylights, change of roof pitch, addition or relocation of mechanical units, or installation of heavier materials than were previously installed. Asphalt shingles shall comply with ASTM D3462. Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. See Table R503.2.1.1 for minimum allowable panel thickness by span and load.) 2018, 2021 IECC: Mass walls shall be in accordance with Section R402.2.5 (N1102.2.5 in 2018 IRC). Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Wood shakes shall comply with the requirements of Table R905.8.5. The installation of wood shakes shall comply with the provisions of this section. Asphalt shingles shall be used only on roof. Sprayed polyurethane foam roofs shall have a design. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Modified bitumen membrane roofs shall have a design. Slate shingles shall be fastened to solidly sheathed roofs. Slate shingles shall be secured to the roof with two fasteners per slate. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. . Roofing materials must be installed in accordance with Chapter 9 of the 2020 Minnesota Residential Code and the manufacturer's installation Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. The installation of asphalt shingles shall comply with the provisions of this section. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. 2018 IRC. The GAF VersaShield Fire-Resistant Roof Deck Protection may be placed under or over the counterbattens. redundant requirements for stud nailing, and create consistency in the IRC for roof sheathing attachment. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. conditions about your roof that may limit your product choices or affect the cost of your roofing job. Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. DEWALT Building Code Reference: Based on the 2018 International Residential Code | Books & Magazines, Textbooks, Education & Reference, Dictionaries & Reference | eBay! Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. Modified bitumen roofing shall comply with the standards in Table 905.11.2. A base sheet that complies with the requirements of Section 1507.11.2 of the. 12 oz/sq ft for preformed metal shingle systems. Slate shingles shall comply with ASTM C406. R905.2Asphalt shingles. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Modified bitumen roofing shall comply with the standards in Table R905.11.2. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. The installation of asphalt shingles shall comply with the provisions of this section. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Asphalt shingles shall be used only on roof. For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s. The installation of wood shingles shall comply with the provisions of this section. Install 7/16 in.-structural sheathing (OSB or plywood) on the vertical face of the gable end wall. Slate shingles shall comply with ASTM C406. For SI: 1 ounce per square foot = 0.305 kg/m, The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer's, Modified bitumen roofing shall have a design. Drip edges shall extend not less than. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Exception: Detached accessory structures not containing conditioned floor area. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer's, Where required, ice barriers shall comply with, Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions. Part III Building Planning and Construction, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections 904 and 905. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). 1. (914 mm). Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. For closed valleys (valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D6380 and not less than 36 inches wide (914 mm) or valley lining as described in Item 1 or 2 shall be permitted. Asphalt shingle packaging shall bear a. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. The installation of wood shingles shall comply with the provisions of this section. For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D3909 or ASTM D6380 Class M, shall be permitted. Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. Minimum headlap for slate shingles shall be in accordance with Table R905.6.5. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019-inch (0.5 mm) thickness or mineral-surfaced roll roofing weighing not less than 77 pounds per 100 square feet (4 kg/m. For SI: 1 ounce per square foot = 0.305 kg/m. The installation of modified bitumen roofing shall comply with the provisions of this section. Roof valley flashing shall be not less than No. Asphalt shingles shall be fastened to solidly sheathed decks. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s. 3. Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019-inch (0.5 mm) thickness or mineral-surfaced roll roofing weighing not less than 77 pounds per 100 square feet (4 kg/m. Where the existing roof covering is slate, clay, cement or asbestos-cement tile. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. IRC Section 301.3 Story Height: The ability is restored to construct a story of a dwelling using 12-foot high bearing walls if the wall studs are engineered for gravity loads, wall bracing amounts are increased, and a roof or celling diaphragm provides support to the studs. Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. 233 0 obj <>/Filter/FlateDecode/ID[<4D23A6406EEE004484C52F82EDD55E2A>]/Index[201 60]/Info 200 0 R/Length 141/Prev 323429/Root 202 0 R/Size 261/Type/XRef/W[1 3 1]>>stream Part III Building Planning and Construction, R907 Rooftop-Mounted Photovoltaic Panel Systems, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. The installation of liquid-applied roofing shall comply with the provisions of this section. Slate shingles shall comply with ASTM C 406. The installation of wood shingles shall comply with the provisions of this section. A liquid-applied protective coating that complies with Table R905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. Valley flashing shall be not less than 15 inches (381 mm) wide. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Asphalt shingle packaging shall bear a, Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer, but not less than four fasteners per strip shingle or two fasteners per individual shingle. For SI: 1 ounce per square foot = 0.305 kg/m, The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer's, Modified bitumen roofing shall have a design. R905.2.2 Slope. Each bundle of shakes shall be identified by a. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. The International Residential Code (IRC) and the Residential Edition of the Florida Building Code (FBC) both refer to Table R503.2.1.1(1) of the APA Engineered Wood Construction Guide for specs. A base sheet that complies with the requirements of. Rooftop-mounted photovoltaic systems shall be installed in accordance with the manufacturer's instructions. The 4-inch-wide (102 mm) strips of self-adhering polymer-modified-bitumen membrane Where the existing roof covering is wood shake, slate, clay, cement or asbestos-cement tile. Sprayed polyurethane foam roofs shall have a design. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. hb```g``:AX,;nkga3l~/ * satisfy the requirements of 2021 IBC Section 1512, 2018 and 2015 IBC Section 1511, 2012, 2009 and 2006 IBC Section 1510, 2018 and 2021, 2018 and 2015 IRC Section R908 or 2012, 2009 or 2006 IRC Section R907. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch- diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. Asphalt shingles shall be used only on roof. A liquid-applied protective coating that complies with Table R905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. The installation of thermoset single-ply roofing shall comply with the provisions of this section. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Asphalt shingles shall be fastened to solidly sheathed decks. Where required, ice barriers shall comply with Section 905.1.2. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of shingle roofs. 12 oz/sq ft for preformed metal shingle systems. 2018 International Residential Code (IRC) COPYRIGHT PREFACE EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE arrow_right CHAPTER 1 SCOPE AND ADMINISTRATION arrow_right CHAPTER 2 DEFINITIONS arrow_right CHAPTER 3 BUILDING PLANNING arrow_right CHAPTER 4 FOUNDATIONS arrow_right CHAPTER 5 FLOORS arrow_right CHAPTER 6 WALL CONSTRUCTION arrow_right Liquid-applied roofing shall have a design. Flashing and counterflashing shall be made with sheet metal. Wood shingles shall be laid with a side lap not less than 1, NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES, Roof flashing shall be not less than No. If re-roofing over wood shingle, or wood shake roofs, additional code requirements may apply. Asphalt shingles shall be used only on roof. Minimum headlap for slate shingles shall be in accordance with Table R905.6.5. The ratio changes based on climate severity. The installation of slate shingles shall comply with the provisions of this section. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. Flashing against a vertical front wall, as well as soil. the 2018 International Residential Code (IRC) simplified wall bracing requirements. %PDF-1.6 % Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019-inch (0.5 mm) thickness or mineral-surfaced roll roofing weighing not less than 77 pounds per 100 square feet (4 kg/m. Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. Materials and methods of application used for re-covering or replacing an existing, The structural roof components shall be capable of supporting the, Roof replacement shall include the removal of existing layers of, Flashings shall be reconstructed in accordance with. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s. For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D3909 or ASTM D6380 Class M, shall be permitted. Liquid-applied roofing shall be installed in accordance with this chapter and the, Where required, an ice barrier shall comply with, In areas where there has been a history of ice forming along the eaves causing a backup of water, as designated in, The use of above-deck thermal insulation shall be permitted provided that such insulation is covered with an. R905.2 Asphalt shingles. 2. For closed valleys (valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D6380 and not less than 36 inches wide (914 mm) or valley lining as described in Item 1 or 2 shall be permitted. Section R804 Cold-Formed Steel Roof Framing Section R806 Roof Ventilation Section R807 Attic Access Chapter 9 Roof Assemblies The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. Wolf Hollow Chapter 1, Fayette County Magistrate Court Wv, Airbnb With Hot Tub Greensboro Nc, 2017 2018 Unc Basketball Roster, Mercari Ship On Your Own Option, What Is Chip Kullik Doing Now, Barbara Meshad Dooley Age, The Glamorous Imperial Concubine Happy Or Sad Ending, Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. Stainless steel fasteners are acceptable for metal roofs. Above-deck thermal insulation board shall comply with the standards in Table R906.2. Mineral-surfaced roll roofing shall not be applied on roof. Sprayed polyurethane foam roofs shall have a design. Reroofing shall not be required to meet the minimum design, For roofs that provide positive drainage, recovering or replacing an existing, Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and do not rely on existing roofs and, Where the existing roof has two or more applications of any type of. Asphalt shingle packaging shall bear a. The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. 2018 IRC Simplified Wall Bracing Provisions 4 Objectives Upon completion, participants will be better able to: 1. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s. Stainless steel fasteners are acceptable for metal roofs. For closed valleys (valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D6380 and not less than 36 inches wide (914 mm) or valley lining as described in Item 1 or 2 shall be permitted. 2018 International Residential Code (IRC) COPYRIGHT PREFACE EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE arrow_right CHAPTER 1 SCOPE AND ADMINISTRATION arrow_right CHAPTER 2 DEFINITIONS arrow_right CHAPTER 3 BUILDING PLANNING arrow_right CHAPTER 4 FOUNDATIONS arrow_right CHAPTER 5 FLOORS arrow_right CHAPTER 6 WALL CONSTRUCTION arrow_right 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a.